Diagnostic Method
- Abnormality Judgment
Judge as NG when the continuous time of completing the malfunction criteria below becomes 15 seconds or more.
Judgment Value
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Fuel tank pressure | ≥ 7.98 kPa (59.85 mmHg, 2.36 inHg) |
| Fuel temperature | < 35°C (95°F) |
| Atmospheric pressure | 75.1 kPa (563 mmHg, 22.2 inHg) |
Time Needed for Diagnosis: 15 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
- Normality Judgment
Judge as OK when the criteria below are met.
Judgment Value
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Fuel tank pressure | < 7.98 kPa (59.85 mmHg, 2.36 inHg) |