Diagnostic Method
- Abnormality Judgment
Judge as NG when the continuous time of completing the malfunction criteria below becomes 2.5 seconds or more.
Judgment Value
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery voltage | ≥8V |
| Fuel level | ≥9.6 l (2.54 US gal, 2.11 Imp gal) |
| Fuel pump control unit output diagnosis signal | Low |
Time Needed for Diagnosis: 2.5 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
- Normality Judgment
Judge as OK and clear the NG when the malfunction criteria below are met.
Judgment Value
JUDGMENT VALUE REFERENCE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Battery voltage | ≥8V |
| Fuel level | ≥ 9.6 l (2.54 US gal, 2.11 Imp gal) |
| Fuel pump control unit output diagnosis signal | High |