Diagnostic Method
Abnormality Judgment
Judge as ON NG when the continuous time of completing the malfunction criteria below becomes more than 3 minutes.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Engine speed | > 500 rpm |
| Starter OFF signal | Not detected |
| Battery voltage | > 8 V |
Time Needed for Diagnosis: 180 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.
Normality Judgment
Judge as ON OK and clear the NG when the malfunction criteria below are met.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Starter OFF signal | Detected |
| Battery voltage | > 8 V |