Diagnostic Method
Abnormality Judgment
Judge as NG when the continuous time of completing the malfunction criteria below becomes 15 seconds or more.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Fuel tank pressure | > 7.98 kPa (59.85 mmHg, 2.36 inHg) |
| Fuel temperature | < 35°C (95°F) |
| Atmospheric pressure | ≥ 75.1 kPa(563 mmHg, 22.2 inHg) |
Time Needed for Diagnosis: 15 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgment
Judge as OK when the criteria below are met.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Fuel tank pressure | ≤ 7.98 kPa (59.85 mmHg, 2.36 inHg) |