Diagnostic Method
Abnormality Judgment
Judge as NG when the continuous time of completing the malfunction criteria below becomes 0.5 seconds or more.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Output voltage | < 0.166 V |
| Ignition switch | ON |
Time Needed for Diagnosis: 0.5 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgment
Judge as OK and clear the NG when the malfunction criteria below are met.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Output voltage | ≥ 0.166 V ON |
| Ignition switch | ON |