Diagnostic Method
Abnormality Judgment
Judge as NG when the continuous time when the following conditions are established is more than 2 seconds.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| Duty ratio | < 7% |
| Control current | ≥ 0.465 A |
Time Needed for Diagnosis: 2 seconds
Malfunction Indicator Light Illumination: Illuminates as soon as a malfunction occurs.
Normality Judgment
Judge as OK and clear the NG when the continuous time when the following conditions are established are more than 2 seconds.
Judgment Value
JUDGMENT VALUE CHART
| Malfunction Criteria | Threshold Value |
|---|---|
| |Oil switching solenoid valve current target current value - oil switching solenoid valve current value| | < 0.08 A |