LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2006 >> Forester XT Limited, Standard >> Repair and Diagnosis >> Body & Frame >> Door Locks >> Security And Locks >> Security System >> Inspection >> Check Power Supply And Ground Circuit

Check Power Supply And Ground Circuit

DIAGNOSTIC PROCEDURE CHART

Step Check Yes No
1 CHECK POWER SUPPLY. 
  1. Disconnect the keyless entry control module harness connector.
  2. Measure the voltage between harness connector terminal and chassis ground.

    Connector & terminal 

    (B176) No. 2, 26 (+) - Chassis ground (-): 

Is the voltage more than 10 V? Go to step 2.  Check the harness for open circuits or shorts between the keyless entry control module and the fuse.
2 CHECK GROUND CIRCUIT. 
Measure the resistance between harness connector terminal and chassis ground.

Connector & terminal 

(B176) No. 14 - Chassis ground: 

Is the resistance less than 10Ω? The power supply and ground circuit are OK. Repair the harness.