Check Power Supply And Ground Circuit
DIAGNOSTIC PROCEDURE CHART
| Step | Check | Yes | No |
|---|---|---|---|
1 CHECK POWER SUPPLY.
|
Is the voltage more than 10 V? | Go to step 2. | Check the harness for open or short circuit between body integrated unit and fuse. |
| 2 CHECK GROUND CIRCUIT. Measure the resistance between harness connector terminal and chassis ground. Connector & terminal (B280) No. 4, 13 - Chassis ground: |
Is the resistance less than 10 Ω | The power supply and ground circuit are OK. | Repair the harness. |