Check Power Supply And Ground Circuit

DIAGNOSTIC PROCEDURE CHART

Step Check Yes No
1 CHECK POWER SUPPLY.
  1. Disconnect the harness connector of body integrated unit.
  2. Measure the voltage between harness connector terminal and chassis ground.

    Connector & terminal 

    (B280) No. 1,2 (+) - Chassis ground (-): 

Is the voltage more than 10 V? Go to step 2.  Check the harness for open or short circuit between body integrated unit and fuse.
2 CHECK GROUND CIRCUIT. 
Measure the resistance between harness connector terminal and chassis ground.

Connector & terminal 

(B280) No. 4, 13 - Chassis ground: 

Is the resistance less than 10 Ω The power supply and ground circuit are OK. Repair the harness.