Normality Judgment
Judge OK and clear the NG when the continuous time of completing the malfunction criteria below becomes more than 0.262 seconds.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria |
Threshold Value |
| (Atmospheric - manifold absolute pressure) |
< 26.7 kPa (200 mmHg, 7.88 inHg) |