Diagnostic Method
Judge NG when the continuous time of completing the malfunction criteria below becomes more than 5 seconds.
Judge OK and clear NG when the continuous time of not completing the malfunction criteria below becomes more than 5 seconds.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Sub feedback learning value | >/= 0.018 |
Time Needed for Diagnosis: 5 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous drive cycles.