Abnormality Judgment
Judge NG when the malfunction criteria below becomes.
Judgment Value
JUDGMENT VALUE
| Malfunction Criteria | Threshold Value |
|---|---|
| Duty ratio of 'ON' | < 75% |
| Terminal output voltage | Low |
Time Needed for Diagnosis: 2.5 seconds
Malfunction Indicator Light Illumination: Illuminates when malfunction occurs in 2 continuous driving cycles.