Fail Safe
- Knocking compensation
At normal condition: Self-learning ignition advance value = knock F/B advance + overall self-learning advance value + partial self-learning advance value
When malfunctioning: Self-learning ignition advance value = -6°CA (6°CA retard)
knock F/B advance value = 0°CA
Prohibit overall self-learning
Partially prohibit self-learning