Ignition Key Lock: Inspection
- Remove the instrument panel lower cover.
- Remove the lower column cover.
- Unfasten the hold-down clip which secures harness and disconnect the connector of ignition switch from body harness.
- Turn the ignition key plate to each position and check the continuity between terminals of ignition connector.SWITCH POSITION TERMINAL NO SPECIFICATION
Switch position Terminal No. Standard LOCK - - ACC No. 1 and No. 2 Less than 1 ON No. 1 and No. 2
No. 1 and No. 4
No. 2 and No. 4Less than 1 ST No. 1 and No. 3
No. 1 and No. 4
No. 3 and No. 4Less than 1 If NG, replace the ignition switch.