LEMON Manuals: Even more car manuals for everyone
Home >> Subaru >> 2004 >> Forester XT, Automatic >> Repair and Diagnosis >> External Pages >> Different car >> Section 139 (Starting System & Charging System (H4SO)) >> General Description >> Specifications

Section 139 (Starting System & Charging System (H4SO)): General Description: Specifications

WARNING: This page is about a different car, the 2005 Subaru Forester. However, it is still accessible from the selected car via links, so may be relevant.
GENERAL SPECIFICATIONS

Item Designation
Starter Type Reduction type
Vehicle type MT AT
Model M000T30471 M000T20171
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 1.0 kW 12 V - 1.4 kW
Direction of rotation Counterclockwise (viewed from pinion gear side)
Number of pinion teeth 8 9
No-load characteristics Voltage 11 V
Current 95 A or less 90 A or less
Rotating speed 2,500 RPM or more 2,000 RPM or more
Load characteristics Voltage 8.0 V 8.0 V
Current 280 A 280 A
Torque 8.5 N.m (0.87 kgf-m, 6.27 ft-lb) or more 9.8 N.m (1.0 kgf-m, 7.23 ft-lb) or more
Rotating speed 970 RPM or more 1,000 RPM or more
Lock characteristics Voltage 4 V 3.5 V
Current 680 A or less 960 A or less
Torque 17 N.m (1.73 kgf-m, 12.5 ft-lb) or more 31 N.m (3.16 kgf-m, 22.9 ft-lb) or more
Generator Type Rotating-field three-phase type, Voltage regulator built-in type, with load response control system
Model A002TB2891
Manufacturer Mitsubishi Electric
Voltage and output 12 V - 90 A
Polarity on ground side Negative
Rotating direction Clockwise (viewed from pulley side)
Armature connection 3-phase Y-type
Output current 1,500 RPM - 36 A or more
2,500 RPM - 65 A or more
5,000 RPM - 86 A or more
Regulated voltage 14.1 - 14.8 V [20°C (68°F)]
Battery Voltage and output MT: 12 V - 48 AH (55D23L)
AT: 12 V - 52AH (75D23L)