Flow Control: Notes

The variable capacity pump changes its delivery rate per rotation by changing the degree of eccentricity of the cam ring according to its rotating speed (engine speed).

Fig 1: Variable Capacity Pump Flow Control Chart
G02861416Courtesy of SUBARU OF AMERICA, INC.
NOTE: In the following description, pump speed ranges will be indicated using the speed points A through D shown in the drawing above.