Dual-Pressure Switch

Connect manifold gauge set to high pressure service valve. Disconnect dual-pressure switch harness connector. Check continuity between dual-pressure switch terminals with system at specified pressures. See DUAL-PRESSURE SWITCH OPERATION  table. If continuity is not as specified, replace dual-pressure switch.

DUAL-PRESSURE SWITCH OPERATION

Application & psi (kg/cm2 ) Continuity
High Pressure
Increasing To 413-441 (29-31) No
Decreasing To 313-396 (22-28) Yes
Low Pressure
Increasing To 22-30 (1.5-2.1) No
Decreasing To 23-33 (1.6-2.3) Yes