Diagnosis Warning
When any of the following problems occur, the charge light will illuminate.
- No voltage generation: Brush wear exceeds specified limits, field coil circuit is broken, etc.
- Excessive output: Output voltage is greater than about 16 volts.
- Terminal "B" disconnection: Harness is disconnected from generator terminal "B".
- Terminal "S" disconnection: Harness is disconnected from generator terminal "S". In this case, voltage is slightly greater than specified regulated voltage; however, voltage regulation is still controlled and battery is prevented from being overcharged.