Blower Motor
Disconnect blower motor connector. Connect battery voltage to blower motor Black /Red wire terminal. Connect Black /Yellow wire terminal to ground. Ensure blower motor operates smoothly. Transpose power and ground leads. Ensure blower motor operates smoothly and quietly in reverse direction. Replace blower motor if it does not test as specified.