Fuel Injector
- Using a stethoscope or long screwdriver, ensure that there is an operating noise (clicking noise) from injector. If operating noise cannot be heard, check resistance of injector on control side.
- Turn ignition switch to "OFF" position. Disconnect connector from control unit. Use an ohmmeter to measure resistance between terminal No. 43 (RW) and terminal No. 48 (RB) of harness connector. A reading of .5-2.0 ohms should be present.
- If resistance is not within specifications. Disconnect connector from injector. Measure resistance between terminals of connector on injector side. Resistance should be .5-2.0 ohms. If resistance is not within specifications replace injector.