Hold-In Test

Connect test equipment to starter. See Fig 1. Disconnect "M" terminal on Subaru. The starter pinion should remain projected. If not, replace hold-in coil.

Fig 1: Solenoid Test Hookup "M" (field) lead should be disconnected at solenoid.
G29425