LEMON Manuals: Even more car manuals for everyone
Home >> Scion >> 2016 >> iM Standard Trans >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control System - Diagnostic Codes (P0010-P0196) >> SFI System >> DTC P0106: Manifold Absolute Pressure Circuit Problem [06/2015 - ] >> Monitor Strategy

Monitor Strategy

Related DTCs P0106: Manifold absolute pressure sensor stuck
Required Sensors/Components (Main) Manifold absolute pressure sensor
Required Sensors/Components (Related) -
Frequency of Operation Continuous
Duration 6 seconds
MIL Operation 2 driving cycles
Sequence of Operation None