Integration Relay (EFI No. 2)
INTEGRATION RELAY (EFI NO. 2)
| Tester Connection |
Condition |
Specified Condition |
| 1C-1 - 1B-8 |
Battery voltage not applied to terminals 1B- 6 and 1B-7 |
10 kΩ or higher |
| Battery voltage applied to terminals 1B-6 and 1B-7 |
Below 1 Ω |