How To Proceed With Troubleshooting [01/2014 - ]
HINT:
- Use these procedures to troubleshoot the power window control system.
- *: Use the Techstream.
- VEHICLE BROUGHT TO WORKSHOP
NEXT: Go to next step
- INSPECT BATTERY VOLTAGE
Standard voltage
11 to 14 V
If the voltage is below 11 V, recharge or replace the battery before proceeding.
NEXT: Go to next step
- CHECK COMMUNICATION FUNCTION OF LIN COMMUNICATION SYSTEM*
- Check if the LIN communication system is functioning normally.RESULT
Result Proceed to LIN DTC is not output A LIN DTC is output B B → GO TO LIN COMMUNICATION SYSTEM. Refer to HOW TO PROCEED WITH TROUBLESHOOTING [01/2014 - ]
A: Go to next step
- Check if the LIN communication system is functioning normally.
- CHECK FOR DTC*
- Clear the DTC. Refer to DTC CHECK / CLEAR [05/2013 - ] .
- Recheck for DTC. Refer to DTC CHECK / CLEAR [05/2013 - ] .RESULT
Result Proceed to No DTCs are output A DTC B2311, B2312 or B2313 is output B B → GO TO DIAGNOSTIC TROUBLE CODE CHART. Refer to DIAGNOSTIC TROUBLE CODE CHART [01/2014 - ]
A: Go to next step
- PROBLEM SYMPTOMS TABLE
- Refer to Problem Symptoms Table. Refer to PROBLEM SYMPTOMS TABLE [01/2014 - ] .RESULT
Result Proceed to Fault not listed in problem symptoms table A Fault listed in problem symptoms table B B → ADJUST, REPAIR OR REPLACE IN ACCORDANCE WITH PROBLEM SYMPTOMS TABLE
A: Go to next step
- Refer to Problem Symptoms Table. Refer to PROBLEM SYMPTOMS TABLE [01/2014 - ] .
- OVERALL ANALYSIS AND TROUBLESHOOTING*
- Operation Check. Refer to OPERATION CHECK [05/2013 - ] .
- Terminals of ECU. Refer to TERMINALS OF ECU [01/2014 - ] .
- Data List / Active Test. Refer to DATA LIST / ACTIVE TEST [05/2013 - ] .
NEXT: Go to next step
- REPAIR OR REPLACE RESULT
Result Proceed to Power window regulator motor assembly LH replaced or removed/installed A Power window regulator motor assembly LH not replaced or removed/installed B B → GO TO STEP 9
A: Go to next step
- RESET POWER WINDOW REGULATOR
- If a power window regulator switch LED is blinking, initialize the power window regulator. Refer to FAIL-SAFE CHART [05/2013 - ] .
NEXT: Go to next step
- If a power window regulator switch LED is blinking, initialize the power window regulator. Refer to FAIL-SAFE CHART [05/2013 - ] .
- CONFIRMATION TEST
NEXT → END