  1. INSTALL INDICATOR LIGHT WIRE SUB-ASSEMBLY 
    1. Install the indicator light wire sub-assembly into the shift lock control unit assembly.
      Fig 1: Identifying Indicator Light Wire Sub-Assembly
      GTY166332Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      NOTE:

      Fit the indicator light wire sub-assembly into the shift lock control unit, as shown in the illustration.

  2. INSTALL SHIFT LOCK RELEASE BUTTON 
    1. Install the shift lock release button and shift lock release spring into the shift lock control unit assembly.
      Fig 2: Identifying Shift Lock Release Button
      GTY158783Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  3. INSTALL NO. 2 POSITION INDICATOR SLIDE COVER 
    1. Install the No. 2 position indicator slide cover onto the position indicator slide cover.
      Fig 3: Identifying No. 2 Position Indicator Slide Cover
      GTY163228Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  4. INSTALL POSITION INDICATOR SLIDE COVER 
    1. Install the position indicator slide cover onto the shift lock control unit assembly.
      Fig 4: Identifying Position Indicator Slide Cover
      GTY158782Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      NOTE:

      Install the slide cover onto the shift lock control unit with the arrow mark directed forward.

  5. INSTALL SHIFT LOCK RELEASE BUTTON COVER 
    1. Install the shift lock release button cover onto the upper position indicator housing.
  6. INSTALL NO. 2 CONTROL POSITION INDICATOR PLATE 
    1. Engage the claw, and install the No. 2 control position indicator plate onto the upper position indicator housing.
      Fig 5: Identifying Control Position Indicator Plate Claw
      GTY157862Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
  7. INSTALL UPPER POSITION INDICATOR HOUSING 
    1. Engage the 4 claws, and install the upper position indicator housing onto the shift lock control unit assembly.
      Fig 6: Identifying Upper Position Indicator Housing Claws
      GTY166129Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
      NOTE:

      Securely engage the 4 claws.