Home >> Scion >> 2013 >> iQ Base >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 84 (Smart Key System (Start Function) (Diagnostic Codes & Symptom Tests) (Electric)) >> SMART KEY SYSTEM (for Start Function) >> Symptom Tests >> Power Source Mode does not Change to ON (IG and ACC) >> Description

Power Source Mode does not Change to ON (IG and ACC): Description

WARNING: This page is about a different variant/trim than selected.

When the electrical key transmitter sub-assembly is in the vehicle and the power switch is pressed, the power management control ECU receives a signal and changes the power source mode.

HINT: 

Problem Symptom Data List Item Active Test Item
Power source mode does not change to on (IG) or on (ACC) Power Source Control 
  • Start Switch1
  • Start Switch2
  • Power Supply Condition
  • IG1 Relay Monitor(Inside)
  • IG2 Relay Monitor(Inside)
  • IG1 Relay Monitor(Outside)
  • IG2 Relay Monitor(Outside)
  • Latch Circuit
  • ACC Relay Monitor
-