LEMON Manuals: Even more car manuals for everyone
Home >> Scion >> 2013 >> iQ Base >> Repair and Diagnosis (Single Page) >> Engine Performance >> System >> Engine Control System (Diagnostic Codes P1604-P2610 & Circuit Tests) (Except Electric) >> SFI System >> EVAP System >> Monitor Result

Monitor Result

Refer to Checking Monitor Status. Refer to CHECKING MONITOR STATUS .

P0456: EVAPORATIVE SYSTEM / SMALL LEAK

Monitor ID Test ID Scaling Unit Description
$3D $C9 Multiply by 0.001 kPa Test value for small leak
P0455: EVAPORATIVE SYSTEM / GROSS LEAK

Monitor ID Test ID Scaling Unit Description
$3D $CA Multiply by 0.001 kPa Test value for gross leak
P2401: EVAPORATIVE SYSTEM / VACUUM PMP OFF

Monitor ID Test ID Scaling Unit Description
$3D $CB Multiply by 0.001 kPa Test value for leak detection pump OFF stuck
P2402: EVAPORATIVE SYSTEM / VACUUM PMP ON

Monitor ID Test ID Scaling Unit Description
$3D $CD Multiply by 0.001 kPa Test value for leak detection pump ON stuck
P2420: EVAPORATIVE SYSTEM / VENT VALVE OFF

Monitor ID Test ID Scaling Unit Description
$3D $CE Multiply by 0.001 kPa Test value for vent valve OFF stuck
P2419: EVAPORATIVE SYSTEM / VENT VALVE ON

Monitor ID Test ID Scaling Unit Description
$3D $CF Multiply by 0.001 kPa Test value for vent valve ON stuck
P043E: EVAPORATIVE SYSTEM / ORIFICE CLOGGED

Monitor ID Test ID Scaling Unit Description
$3D $D0 Multiply by 0.001 kPa Test value for reference orifice low flow
P043F: EVAPORATIVE SYSTEM / ORIFICE HI-FLW

Monitor ID Test ID Scaling Unit Description
$3D $D1 Multiply by 0.001 kPa Test value for reference orifice high flow
P0441: EVAPORATIVE SYSTEM / PURGE VSV CLOSED

Monitor ID Test ID Scaling Unit Description
$3D $D4 Multiply by 0.001 kPa Test value for purge VSV closed stuck
P0441: EVAPORATIVE SYSTEM / PURGE VSV OPENED

Monitor ID Test ID Scaling Unit Description
$3D $D5 Multiply by 0.001 kPa Test value for purge VSV open stuck
P0441: EVAPORATIVE SYSTEM / PURGE FLOW

Monitor ID Test ID Scaling Unit Description
$3D $D7 Multiply by 0.001 kPa Test value for purge flow insufficient