Typical Enabling Conditions
M/T MODELS
| Monitor runs whenever following DTCs not present | None |
| Time after ignition switch off to ON | 3 seconds or more |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Fuel-cut | ON |
A/T MODELS
| Monitor runs whenever following DTCs not present | None |
| Time after ignition switch off to ON | 3 seconds or more |
| Battery voltage | 8 V or more |
| Ignition switch | ON |
| Starter | OFF |
| Engine | Running |
| Transmission counter gear revolution | 300 RPM or more |
| When either condition below is met | Condition A or B |
| A. When both conditions below are met | - |
| Engine coolant temperature | 20°C (68°F) or higher |
| Time after park/neutral position switch turned from on to off | 2 seconds or more |
| B. When both conditions below are met | - |
| Engine coolant temperature | Below 20°C (68°F) |
| Time after park/neutral position switch turned from on to off | 30 seconds or more |