DTC P1589: Acceleration Sensor Learning Value: Procedure
- PERFORM INITIALIZATION (DECELERATION SENSOR 0 POINT CALIBRATION)
- Perform the deceleration sensor 0 point calibration. Refer to INITIALIZATION
.RESULT
Result Proceed to Deceleration sensor 0 point calibration is completed normally A The MIL illuminates again B
B → See step 3
A: Go to next step
- Perform the deceleration sensor 0 point calibration. Refer to INITIALIZATION
.
- PERFORM CVT OIL PRESSURE CALIBRATION
- Perform the CVT oil pressure calibration. Refer to INITIALIZATION .
NEXT → END
- CHECK YAW RATE AND ACCELERATION SENSOR
- Check the yaw rate and acceleration sensor for any inclination, bracket deformation or installation clearance.
OK
The yaw rate and acceleration sensor is installed correctly.
NG → SECURELY INSTALL YAW RATE AND ACCELERATION SENSOR
OK: Go to next step
- Check the yaw rate and acceleration sensor for any inclination, bracket deformation or installation clearance.
- READ VALUE USING TECHSTREAM (G SENSOR) See step 2
B → See step 7
A: Go to next step
- REPLACE ECM See step 5
NEXT: Go to next step
- PERFORM INITIALIZATION See step 6
NEXT → END
- REPLACE YAW RATE AND ACCELERATION SENSOR See step 3
NEXT: Go to next step
- PERFORM INITIALIZATION See step 6
NEXT → END