VSC Off Switch: Inspection: Inspection
- INSPECT VSC OFF SWITCH
- Measure the resistance according to the value(s) in the table below.
Standard resistance
Tester Connection Switch Condition Specified Condition 3 - 6 Released 10 kΩ or higher 3 - 6 Pushed in Below 25 Ω If the result is not as specified, replace the VSC OFF switch.
- Check illumination operation.
OK
Tester Connection Switch Condition Specified Condition 4 - 5 Battery's positive (+) lead connected to terminal 5 and negative (-) lead to terminal 4 LED illuminates If the result is not as specified, replace the VSC OFF switch.
- Measure the resistance according to the value(s) in the table below.