Service Data
2AZ-FE COOLING - SERVICE DATA
| Thermostat | Valve opening temperature | Standard | 80 to 84°C (176 to 183°F) | |
| Valve lift | Standard | 10 mm (0.39 in.) or more at 95°C (203°F) | ||
| Cooling fan motor | Current | Standard | 1(+) - 2(-) | 5.7 to 7.7 A at 20°C (68°F) |
| No. 2 cooling fan motor | Current | Standard | 1(+) - 2(-) | 5.7 to 7.7 A at 20°C (68°F) |
| No. 1 fan relay (FAN NO. 1) | Resistance | Standard | 3 - 5 | 10 Ω or higher (When battery voltage absent) |
| Below 1 Ω (When battery voltage is applied to terminal 1 and 2) | ||||
| No. 2 fan relay (FAN NO. 2) | Resistance | Standard | 3 - 4 | Below 1 Ω (When battery voltage absent) |
| 3 - 5 | 10 Ω or higher (When battery voltage absent) | |||
| 3 - 4 | 10 Ω or higher (When battery voltage is applied to terminal 1 and 2) | |||
| 3 - 5 | Below 1 Ω. (When battery voltage is applied to terminal 1 and 2) | |||
| No. 3 fan relay (FAN NO. 3) | Resistance | Standard | 3 - 5 | 10 Ω or higher (When battery voltage absent) |
| Below 1 Ω (When battery voltage is applied to terminal 1 and 2) | ||||