Air Cleaner And Hose: Installation
- INSTALL AIR CLEANER ASSEMBLY
- Install the inlet No. 1 air cleaner onto the air cleaner case.
- Install the No. 1 air cleaner hose to the air cleaner cap sub-assembly with the air cleaner hose clamp.
Torque: 3.0 N*m (31 kgf*cm, 27 in.*lbf)
- Install the intake air resonator with the air hose clamp.
Torque: 3.0 N*m (31 kgf*cm, 27 in.*lbf)
- Install the air cleaner case with inlet No. 1 air cleaner with the 2 bolts.
Torque: 7.8 N*m (80 kgf*cm, 69 in.*lbf)
- Install the air cleaner filter element.
- Install and lock the air cleaner cap and air cleaner hose and then tighten the air cleaner hose clamp.
Torque: 3.0 N*m (31 kgf*cm, 27 in.*lbf)
- Connect the No. 2 ventilation hose.
- INSTALL MASS AIR FLOW METER (See INSTALLATION )