Valve Body Assembly: Inspection
- INSPECT SHIFT SOLENOID VALVE SL1
- Measure the resistance.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 1 - 2 20°C (68°F) 5.0 to 5.6 Ω - Connect the positive (+) battery lead with a 21 W bulb to terminal 2 and the negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.NOTE: While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
OK:
The solenoid makes an operating sound.
If the resistance is not as specified, replace the shift solenoid valve SL1.
- Measure the resistance.
- INSPECT SHIFT SOLENOID VALVE SL2
- Measure the resistance.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 1-2 20°C (68°F) 5.0 to 5.6 Ω - Connect the positive (+) battery lead with a 21 W bulb to terminal 2 and the negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.NOTE: While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
OK:
The solenoid makes an operating sound.
If the resistance is not as specified, replace the shift solenoid valve SL2.
- Measure the resistance.
- INSPECT SHIFT SOLENOID VALVE SLT
- Measure the resistance.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition 1-2 20°C (68°F) 5.0 to 5.6 Ω - Connect the positive (+) battery lead with a 21 W bulb to terminal 2 and the negative (-) battery lead to terminal 1 of the solenoid valve connector, and check the operation of the valve.NOTE: While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
OK:
The solenoid makes an operating sound.
If the resistance is not as specified, replace the shift solenoid valve SLT.
- Measure the resistance.
- INSPECT SHIFT SOLENOID VALVE DSL
- Measure the resistance.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition Solenoid Connector (DSL) - Solenoid Body (DSL) 20°C (68°F) 11 to 13Ω - Connect the positive (+) battery lead to the terminal of the solenoid connector, and the negative (-) battery lead to the solenoid body, and check the operation of the valve.NOTE: While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
OK:
The solenoid makes an operating sound.
If the resistance is not as specified, replace the shift solenoid valve DSL.
- Measure the resistance.
- INSPECT SHIFT SOLENOID VALVE S4
- Measure the resistance.
Standard resistance
TESTER CONNECTION SPECIFIED CONDITION CHARTTester Connection Condition Specified Condition Solenoid Connector (S4) - Solenoid Body (S4) 20°C (68°F) 11 to 15Ω - Connect the positive (+) battery lead to the terminal of the solenoid connector, and the negative (-) battery lead to the solenoid body, and check the operation of the valve.NOTE: While using the battery during the inspection, do not bring the positive and negative tester probes too close to each other as a short circuit may occur.
OK:
The solenoid makes an operating sound.
If the resistance is not as specified, replace the shift solenoid valve S4.
- Measure the resistance.