Typical Enabling Conditions

TYPICAL ENABLING CONDITIONS

Monitor runs whenever the following DTCs are not present None
Key-off monitor is run when all of the following conditions are met: -
Atmospheric pressure 70 to 110 kPa (525 to 825 mmHg)
Battery voltage 10.5 V or more
Vehicle speed 2.5 mph (4 km/h) or less
Engine switch OFF
Time after key-off 5, 7 or 9.5 hours
EVAP pressure sensor malfunction (P0450, P0452, P0453) Not detected
EVAP canister purge valve Not operated by scan tool
EVAP canister vent valve Not operated by scan tool
EVAP leak detection pump Not operated by scan tool
Both of the following conditions 1 and 2 are met before key-off: -
1. Duration that vehicle has been driven 5 minutes or more
2. EVAP purge operation Performed
ECT 4.4 to 35°C (40 to 95°F)
IAT 4.4 to 35°C (40 to 95°F)

Key-off monitor sequence 1 to 8 

  1. Atmospheric pressure measurement 
    TYPICAL ENABLING CONDITIONS

    Next sequence runs if the following condition is met: -
    Atmospheric pressure change Less than 0.3 kPa (2.25 mmHg) in 1 second
  2. First reference pressure measurement 
    TYPICAL ENABLING CONDITIONS

    Next sequence runs if the following conditions are met: Conditions 1, 2 and 3
    1. EVAP pressure just after reference pressure measurement start -1 kPa (-7.5 mmHg) or less
    2. Reference pressure -4.85 to -1.057 kPa (-36.384 to -7.929 mmHg)
    3. Reference pressure Saturated
  3. EVAP canister vent valve close stuck check 
    TYPICAL ENABLING CONDITIONS

    Next sequence runs if the following condition is met: -
    EVAP pressure change after vent valve is turned ON 0.3 kPa (2.25 mmHg) or more
  4. Vacuum introduction 
    TYPICAL ENABLING CONDITIONS

    Next sequence runs if the following condition is met: -
    EVAP pressure Saturated within 15 minutes
  5. EVAP canister purge valve close stuck check 
    TYPICAL ENABLING CONDITIONS

    Next sequence runs if the following condition is met: -
    EVAP pressure change after purge valve is opened 0.3 kPa (2.25 mmHg) or more
  6. Second reference pressure measurement 
    TYPICAL ENABLING CONDITIONS

    Next sequence runs if the following conditions are met: Conditions 1,2,3 and 4
    1. EVAP pressure just after reference pressure -1 kPa (-7.5 mmHg) or less
    2. Reference pressure -4.85 to -1.057 kPa (-36.384 to -7.929 mmHg)
    3. Reference pressure Saturated
    4. Difference between first reference pressure and second reference pressure Less than 0.7 kPa (5.25 mmHg)
  7. Leak check 
    TYPICAL ENABLING CONDITIONS

    Next sequence runs if the following condition is met: -
    EVAP pressure when vacuum introduction is complete Lower than second reference pressure
  8. Atmospheric pressure measurement 
    TYPICAL ENABLING CONDITIONS

    EVAP monitor is complete if the following condition is met: -
    Atmospheric pressure difference between sequence 1 and 8 Within 0.3 kPa (2.25 mmHg)