Typical Malfunction Thresholds
TYPICAL MALFUNCTION THRESHOLDS
| Either of the following conditions 1 or 2 is met: | - |
| 1. Frequency that both of the following conditions (a) and (b) are met: | 5 times or more |
| (a) Engine RPM - Target engine RPM | Less than -100 rpm, or more than 150 rpm |
| (b) Vehicle condition | Stop after vehicle was driven at 6.25 mph (10 km/h) or more |
| 2. Frequency that both of the following conditions (c) and (d) are met: | Once |
| (c) Engine RPM - Target engine RPM | Below -100 rpm, or 150 rpm or more (A/C: OFF) |
| (d) IAC flow rate learning value | 1.3 L/sec or less, or 6 L/sec or more |