LEMON Manuals: Even more car manuals for everyone
Home >> Scion >> 2006 >> xB Automatic >> Repair and Diagnosis >> Transmission >> Automatic Trans >> U340E Automatic Transaxle >> Shift Lock System >> On-Vehicle Inspection

On-Vehicle Inspection

  1. CHECK SHIFT LOCK OPERATION 
    1. Adjust the shift lever to the P position.
    2. Turn the ignition switch to the LOCK position.
    3. Check that the shift lever cannot be adjusted to any position other than P.
    4. Turn the ignition switch to the ON position, depress the brake pedal and check that the shift lever can be adjusted to all positions.

      If the operation cannot be done as specified, inspect the shift lock control switch.

  2. CHECK SHIFT LOCK RELEASE BUTTON OPERATION 
    1. When operating the shift lever with the shift lock release button pressed and the ignition switch in the ACC or ON position, check that the lever can be adjusted to all positions.

      If the operation cannot be done as specified, check the shift lever assembly installation condition.

  3. CHECK KEY INTERLOCK OPERATION 
    1. Turn the ignition switch to the ON position.
    2. Depress the brake pedal and adjust the shift lever to any position other than P.
    3. Check that the ignition switch cannot be turned to the LOCK position.
    4. Adjust the shift lever to the P position, turn the ignition switch to the LOCK position and check that the ignition key can be removed.

      If the operation cannot be done as specified, inspect the shift lock control switch.

  4. INSPECT SHIFT LOCK CONTROL SWITCH 
    1. Measure the voltage according to the value(s) in the table below.

      HINT:

      Do not disconnect the shift lock control switch connector.

      Standard voltage 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Connection Condition Specified Condition
      5 (IG) - 1 (E) Ignition switch ON 10 to 14 V
      5 (IG) - 1 (E) Ignition switch OFF Below 1 V
      3 (STP) - 1 (E) Depress brake pedal 10 to 14 V
      3 (STP) - 1 (E) Release brake pedal Below 1 V
      Fig 1: Identifying Shift Lock Control Switch Connector Terminal (IG, STP E)
      G04227535Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002
    2. Measure the resistance according to the value(s) in the table below.

      Standard resistance 

      TESTER CONNECTION SPECIFIED CONDITION

      Tester Condition Condition Specified Condition
      1 (E) - Body ground Always Below 1 Ω

      If the result is not as specified, replace the shift lock control switch.

      Fig 2: Identifying Shift Lock Control Switch Connector Terminal (E)
      G04227536Courtesy of © TOYOTA, LICENSE AGREEMENT TMS1002