Typical Malfunction Thresholds
P0505 IAC functional check:
P0505 IAC FUNCTIONAL CHECK
| When either condition below is met: | 1 or 2 |
| 1. Frequency that both of following conditions (a) and (b) set | 5 times or more |
| (a) Engine rpm - Target engine rpm | Less than -100 rpm, or more than 150 rpm |
| (b) Vehicle condition | Stop after vehicle was driven by 10 km/h (6.25 mph) or more |
| 2. Frequency that both of following conditions (c) and (d) set | Once |
| (c) Engine rpm - Target engine rpm | Less than -100 rpm, or more than 150 rpm |
| (d) IAC flow rate learning value | 0.55 L/sec. or less, or 2.75 L/sec. or more |
P0505 IAC range check:
P0505 IAC RANGE CHECK REFERENCE
| Number of missed output voltage change | 2,000 times or more |
P0511:
DIAGNOSIS PROCEDURE
| Number of missed output voltage change | 1,000 times or more |