MONITOR RESULT INFORMATION - FRONT HEATED OXYGEN SENSOR (BANK 1 SENSOR 1)

Monitor ID Test ID Scaling Unit Description of Test Value
$01 $03 Multiply by 0.001 V Criteria of Lean sensor. O2S is Lean when voltage is lower than this value
$01 $04 Multiply by 0.001 V Criteria of Rich sensor. O2S is Rich when voltage is higher than this value
$01 $05 Multiply by 0.001 Seconds Rich - Lean switch time
$01 $06 Multiply by 0.001 Seconds Lean - Rich switch time
$01 $07 Multiply by 0.005 V Minimum sensor voltage
$01 $08 Multiply by 0.005 V Maximum sensor voltage
$01 $81 Multiply by 0.001 Seconds Duration while sensor voltage stuck Lean or Rich
MONITOR RESULT INFORMATION - REAR HEATED OXYGEN SENSOR (BANK 1 SENSOR 2)

MID TID Scaling Unit Description
$02 $05 Multiply by 0.001 Seconds Rich - Lean switch time
$02 $06 Multiply by 0.001 Seconds Lean - Rich switch time
$02 $07 Multiply by 0.001 V Minimum sensor voltage
$02 $08 Multiply by 0.001 V Maximum sensor voltage
$02 $8A Multiply by 1 Time Frequency of sensor switching
$02 $8B Multiply by 0.001 Seconds 0.35 to 0.2 V sensor switch time
$02 $8D Multiply by 0.001 Seconds Duration that sensor voltage drops to 0.2 V during fuel cut
MONITOR RESULT INFORMATION - CATALYST (BANK 1)

MID TID Scaling Unit Description
$21 $A1 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$21 $A2 Multiply by 0.0003 No dimension Voltage area ratio of O2S sensor 1 and sensor 2
$21 $A3 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$21 $A4 Multiply by 0.0003 No dimension O2S frequency ratio of sensor 2 and sensor 1
$21 $A5 Multiply by 0.0003 No dimension Locus length ratio of O2S sensor 1 and sensor 2
$21 $A6 Multiply by 0.0003 No dimension Voltage area ratio of O2S sensor 1 and sensor 2
MONITOR RESULT INFORMATION - EVAP (KEY-OFF TYPE)

MID TID Scaling Unit Description
$3D $C9 Multiply by 0.01 kPa Test value for small leak (P0456)
$3D $CA Multiply by 0.01 kPa Test value for gross leak (P0455)
$3D $CB Multiply by 0.01 kPa Test value for leak detection pump stuck OFF (P2401)
$3D $CD Multiply by 0.01 kPa Test value for leak detection pump stuck ON (P2402)
$3D $CE Multiply by 0.01 kPa Test value for vent valve stuck OFF (P2420)
$3D $CF Multiply by 0.01 kPa Test value for vent valve stuck ON (P2419)
$3D $D0 Multiply by 0.01 kPa Test value for reference orifice low flow (P043E)
$3D $D1 Multiply by 0.01 kPa Test value for reference orifice high flow (P043F)
$3D $D4 Multiply by 0.01 kPa Test value for purge VSV stuck closed (P0441)
$3D $D5 Multiply by 0.01 kPa Test value for purge VSV stuck open (P0441)
$3D $D7 Multiply by 0.01 kPa Test value for purge flow insufficient (P0441)
MONITOR RESULT INFORMATION - OXYGEN SENSOR HEATER (BANK 1 SENSOR 1)

MID TID Scaling Unit Description
$41 $90 Multiply by 0.001 A Maximum sensor heater current
MONITOR RESULT INFORMATION - OXYGEN SENSOR HEATER (BANK 1 SENSOR 2)

MID TID Scaling Unit Description
$42 $90 Multiply by 0.001 A Maximum sensor heater current
MONITOR RESULT INFORMATION - MISFIRE - ALL CYLINDERS

MID TID Scaling Unit Description
$A1 $0B Multiply by 1 Time Exponential Weighted Moving Average (EWMA) misfire counts for last 10 driving cycles - Total
$A1 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MONITOR RESULT INFORMATION - MISFIRE - CYLINDER 1

MID TID Scaling Unit Description
$A2 $0B Multiply by 1 Time EWMA misfire counts for last 10 driving cycles - Total
$A2 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MONITOR RESULT INFORMATION - MISFIRE - CYLINDER 2

MID TID Scaling Unit Description
$A3 $0B Multiply by 1 Time EWMA misfire counts for last 10 driving cycles - Total
$A3 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MONITOR RESULT INFORMATION - MISFIRE - CYLINDER 3

MID TID Scaling Unit Description
$A4 $0B Multiply by 1 Time EWMA misfire counts for last 10 driving cycles - Total
$A4 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MONITOR RESULT INFORMATION - MISFIRE - CYLINDER 4

MID TID Scaling Unit Description
$A5 $0B Multiply by 1 Time EWMA misfire counts for last 10 driving cycles - Total
$A5 $0C Multiply by 1 Time Misfire counts for last driving cycle and current driving cycle - Total
MONITOR RESULT INFORMATION - THERMOSTAT

MID TID Scaling Unit Description
$E1 $E8 Multiply by 0.1 °C ECT sensor output when estimated ECT reaches malfunction criteria