Monitor Strategy
MONITOR STRATEGY
| Related DTCs | P0125 | Insufficient coolant temperature for closed loop fuel control |
| Required sensors/components | Main sensors | Engine coolant temperature sensor, cooling system, thermostat |
| Related sensors | Mass air flow sensor | |
| Frequency of operation | Continuous | |
| Duration | 2 minute (at 10°C (50°F) or more engine start temperature) 5 minute (at "-6.6°C (20°F)" to "10°C (50°F)" engine start temperature) 20 minute (at less than -6.6°C (20°F) engine start temperature) |
|
| MIL operation | 2 driving cycles | |
| Sequence of operation | None | |