Typical Enabling Conditions
TYPICAL ENABLING CONDITIONS
| Item | Specification | |
|---|---|---|
| Minimum | Maximum | |
| The Monitor Will Run Whenever The Following DTCs Are Not Present | See "List of Disable a Monitor" table (On LIST OF DISABLE A MONITOR ) | |
| Battery Voltage | 11 V | - |
| Intake Air Temperature | -10 °C (14°F) | - |
| Idle | OFF | |
| Intake Air Amount | 8 g/sec | 25 g/sec |
| Engine Speed | - | 4,500 RPM |
| Engine Coolant Temperature | 75°C (167°F) | - |
| Estimated Catalyst Temperature Conditions Are Met: | 1 And 2 | |
| 1. Estimated Temperature Of Upstream Catalyst | 470°C (878°F) | 800°C (1,472°F) |
| 2. Estimated Temperature Of Downstream Catalyst | 470°C (878°F) | 800°C (1,472°F) |
| Fuel System Status | Closed Loop | |
| Accumulated Time With Above Parameters Are Met | 30 Sec X 2 Times | |