Removal Procedure
- Disconnect the engine wiring harness electrical connector (1) from the mass airflow (MAF)/intake air temperature (IAT) sensor.
- Loosen the air cleaner outlet duct clamp at the air cleaner assembly.
- Remove the air cleaner outlet duct from the air cleaner assembly.
- Disengage the air cleaner cover latches (1).
- Open the air cleaner cover.
- Remove and discard the air filter assembly (2).