Installation Procedure
- Install a NEW air filter assembly.
- Close the air cleaner cover.
- Engage the air cleaner cover latches (1).
- Connect the engine wiring harness electrical connector (1) to the MAF/IAT sensor.
- Install the air cleaner outlet duct to the air cleaner assembly.
- Tighten the air cleaner outlet duct clamp at the air cleaner assembly to 4 N.m (35 lb in).
CAUTION:
Refer to Fastener Caution
.