Liftgate Latch Assembly
- Ignition OFF, disconnect the harness connector at the liftgate latch.
- Install a 20A fused jumper wire between the control terminal 1 and 12 volts. Install a jumper wire between the ground terminal 2 and ground. Verify the liftgate latch activates.
- If the latch does not perform as specified, replace the liftgate latch.