Removal Procedure
- Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnection and Connection (LAT) or Battery Negative Cable Disconnection and Connection (LZ4/LY7) .
- Rotate the drive belt tensioner counterclockwise.
- Remove the accessory drive belt. Refer to Drive Belt Replacement .
- Remove the generator. Refer to Generator Replacement (LZ4) or Generator Replacement (LY7) .
- Remove the drive belt tensioner bolt.
- Remove the drive belt tensioner.
- Remove the drive belt idler pulley bolt.
- Remove the drive belt idler pulley.
- Remove the generator bracket bolts.
- Remove the generator bracket.