Automatic Level Control Inflator Fill Valve Inoperative
Automatic Level Control Inflator Fill Valve Inoperative
| Step | Action | Yes | No |
|---|---|---|---|
| 1 | Did you review the Automatic Level Control System Description and Operation and perform the necessary inspections? | Go to Step 2 | Go to Symptoms - Automatic Level Control |
| 2 |
|
Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
| 3 |
|
Go to Step 4 | Go to Step 8 |
| 4 |
|
Go to Step 5 | Go to Step 6 |
| 5 | Connect a test lamp between the ALC inflator solenoid valve supply voltage circuit and the ground circuit of the ALC air inflator solenoid valve connector. Does the test lamp illuminate? |
Go to Step 9 | Go to Step 7 |
| 6 | Repair the open in the ALC inflator solenoid valve supply voltage circuit. Refer to Wiring Repairs
in Wiring Systems. Did you complete the repair? |
Go to Step 10 | - |
| 7 | Repair the open in the ground circuit of the ALC air inflator solenoid valve connector. Did you complete the repair? |
Go to Step 10 | - |
| 8 | Replace ALC air inflator relay. Refer to Automatic Level Control Relay Replacement . Did you complete the replacement? |
Go to Step 10 | - |
| 9 | Replace the ALC air inflator solenoid valve. Refer to Inflator Solenoid Replacement . Did you complete the replacement? |
Go to Step 10 | - |
| 10 | Operate the system in order to verify the repair. Did you correct the condition? |
System OK | Go to Step 3 |