LEMON Manuals: Even more car manuals for everyone
Home >> Saturn >> 2005 >> Relay AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 23 (Battery, Charging System And Starting System) >> Repair Instructions >> Generator Bracket Replacement >> Removal Procedure

Removal Procedure

WARNING: This page is about a different car, the 2005 Chevrolet Malibu. However, it is still accessible from the selected car via links, so may be relevant.
  1. Disconnect the negative battery cable. Refer to Battery Negative Cable Disconnect/Connect Procedure .
  2. Fig 1: Removing Drive Belt
    GM1239067Courtesy of GENERAL MOTORS CORP.
  3. Rotate the drive belt tensioner counterclockwise.
  4. Remove the accessory drive belt. Refer to Drive Belt Replacement in Engine Mechanical - 3.5L (LX9).
  5. Remove the generator. Refer to Generator Replacement (L61)  or Generator Replacement (LX9) .
  6. Fig 2: Removing Drive Belt Tensioner Bolt
    GM1239042Courtesy of GENERAL MOTORS CORP.
  7. Remove the drive belt tensioner bolt.
  8. Remove the drive belt tensioner.
  9. Remove the drive belt idler pulley bolt.
  10. Remove the drive belt idler pulley.
  11. Fig 3: Removing Generator Bracket Bolts
    GM1239046Courtesy of GENERAL MOTORS CORP.
  12. Remove the generator bracket bolts.
  13. Remove the generator bracket.