LEMON Manuals: Even more car manuals for everyone
Home >> Saturn >> 2005 >> Relay AWD >> Repair and Diagnosis (Single Page) >> Electrical >> Charging Systems >> Battery, Charging System And Starting System >> Description And Operation >> Charging System Description and Operation >> Charging System Operation >> Fuel Economy Mode

Fuel Economy Mode

The BCM will enter Fuel Economy Mode when the calculated ambient air temperature is above 0°C (32°F), the calculated battery current is less than 15 amperes and greater than -8 amperes, and the battery state-of-charge (SOC) is greater than 80 percent. Its targeted generator output voltage is 13 volts. The BCM will exit this mode once the criteria is met for Charge Mode.