Removal Procedure

    Fig 1: Using 15 mm Wrench To Rotate Tensioner Pulley
    GM894336Courtesy of GENERAL MOTORS CORP.
    CAUTION: Refer to Battery Disconnect Caution in Cautions and Notices.
    IMPORTANT: Record all pre-set radio stations.
  1. Disconnect the negative battery cable.
  2. Remove the accessory drive belt.
  3. IMPORTANT: The exhaust system remains hot for extended periods of time.
  4. Remove the 2 belt tensioner to engine block bolts and the tensioner.
  5. Remove the upper generator to engine to block bolts.
  6. CAUTION: Refer to Vehicle Lifting Caution in Cautions and Notices.
  7. Raise the vehicle on a hoist.
  8. Turn the steering wheel into a right turn for access to the lower generator bolt.
  9. Remove the lower generator bolt.
  10. Lower the vehicle.
  11. Separate the generator from the engine block.
  12. Disconnect the 2 generator electrical connectors and remove the generator.