Installation Procedure
- Apply a small amount of anti-seize compound SA P/N 21485279 or equivalent to the threads of the HO2S 2.
- Install the HO2S 2 using the J 39194-C or equivalent. Tighten: Tighten the HO2S 2 sensor-to-exhaust pipe to 45 N.m (33 lb ft).
- Install the HO2S 2 harness clip to the heat shield attachment bolt. Tighten: Tighten the bolt to 4 N.m (35 lb in).
- Connect the HO2S 2 harness connector. Push in the connector until a click is heard, then pull back to confirm a positive engagement.
- Ensure the HO2S 2 harness pigtail connector is secure to the chassis.
NOTE:
Silicone based products will contaminate the HO2S. Use only a nickel based anti-seize compound that does not contain silicone.
NOTE:
Refer to Fastener Notice
in Cautions and Notices.
NOTE:
Do Not apply any material in the HO2S-2 harness connector such as grease or dielectric compound. The wires carry air reference to the sensor in order for the sensor to operate properly.