  1. Disconnect the negative battery cable. Refer to BATTERY NEGATIVE CABLE DISCONNECT/CONNECT PROCEDURE in Battery.
  2. Remove the instrument panel storage compartment. Refer to Compartment Replacement - Instrument Panel (I/P) in Instrument Panel, Gages and Console.
  3. Fig 1: Removing/Installing Right Side Heater Duct Assembly & Retainer
    GM896489Courtesy of GENERAL MOTORS CORP.
  4. Remove the heater outlet retainer.
  5. Remove the heater outlet.
  6. Fig 2: Locating Recirculation Actuator Electrical Connector
    GM894265Courtesy of GENERAL MOTORS CORP.
  7. Disconnect the recirculation actuator electrical connector.
  8. Disconnect the aspirator hose and position the hose aside.
  9. Fig 3: Removing & Installing Blower Motor Control Module
    GM1242398Courtesy of GENERAL MOTORS CORP.
  10. Remove the blower motor resistor screws.
  11. Use the electrical harness to pull the blower motor control module out of the HVAC module.
  12. Disconnect the blower motor control module electrical connector.