Scan Tool Data Definitions
The HVAC Scan Tool Data Definitions contain a brief description of all the scan tool parameters. This list is in alphanumeric order.
- A/C High Side Pressure
-
The scan tool displays -103 to +3119 kPa (-14 to +452 psi). This parameter represents the A/C refrigerant pressure sensor voltage signal converted to pressure.
- A/C High Side Pressure Sensor
-
The scan tool displays 0.00-5.00 Volts. This parameter represents the A/C refrigerant pressure sensor signal.
- A/C Request
-
The scan tool displays Yes or No. The PCM uses the A/C request signal in order to determine if A/C compressor operation is being requested by the HVAC control module.
- A/C Relay Circuit Short to Volts
-
The scan tool displays Yes or No. Yes is displayed if the A/C relay control circuit is shorted to voltage.
- A/C Relay Circuit Open or Short to Ground
-
The scan tool displays Yes or No. Yes is displayed if the A/C relay control circuit is open or shorted to ground.
- A/C Relay Command
-
The scan tool displays On or Off. Represents the PCM commanded state of the A/C compressor clutch relay. The A/C compressor clutch should be engaged when Commanded A/C displays On.
- Auto Switch - Actual
-
The scan tool displays High or Low. When the AUTO button is pressed the scan tool displays High. When released, the scan tool displays Low.
- Auto Switch Command
-
The scan tool displays On or Off. On is displayed when the HVAC control module is in Auto Mode.
- Defrost Switch - Actual
-
The scan tool displays High or Low. When the Defrost button is pressed the scan tool displays High. When released, the scan tool displays Low.
- Defrost Switch Command
-
The scan tool displays On or Off. On is displayed when the Defrost is selected.
- Defrost LED
-
The scan tool displays On or Off. The state of the Defrost LED.
- Economy Switch - Actual
-
The scan tool displays High or Low. When the Economy button is pressed the scan tool displays High. When released, the scan tool displays Low.
- Economy Switch Command
-
The scan tool displays On or Off. On is displayed when the Economy is selected.
- Fan Speed
-
This data indicates the blower motor speed value as a Counts.
- Mix Feedback
-
This data indicates the actual air mix door position.
- Mode Switch - Actual
-
The scan tool displays High or Low. When the Mode button is pressed the scan tool displays High. When released, the scan tool displays Low.
- Mode Switch Command
-
The scan tool displays On or Off. On is displayed when the a Mode is selected.
- Mode Feedback
-
This data indicates the actual air Mode door position.
- Off Switch - Actual
-
The scan tool displays High or Low. When the Off button is pressed the scan tool displays High. When released, the scan tool displays Low.
- Off Switch Command
-
The scan tool displays On or Off. On is displayed when the Off is selected.
- Outside Air Temperature
-
The scan tool displays 0 to 255 counts (0 to 5 volts). The status of the sensor signal circuit is monitored. 0 counts indicates a short to ground, 255 counts indicates an open circuit.
- Passenger Compartment Temperature
-
The scan tool displays 0 to 255 counts (0 to 5 volts). The status of the sensor signal circuit is monitored. 0 counts indicates a short to ground, 255 counts indicates an open circuit.
- Rear Defrost Switch - Actual
-
The scan tool displays High or Low. When the Rear Defrost button is pressed the scan tool displays High. When released, the scan tool displays Low.
- Rear Defrost Switch Command
-
The scan tool displays On or Off. On is displayed when the Rear Defrost is selected.
- Rear Defrost Feedback
-
The scan tool displays High or Low. When the Rear Defrost is On the scan tool displays High.
- Recirculation LED
-
The scan tool displays On or Off. The state of the Recirculation LED.
- Recirculation Switch Command
-
The scan tool displays On or Off. On is displayed when the Recirculation is selected.
- Sun Load Sensor
-
The scan tool displays 0 to 255 counts. The signal output from the Sun Load Sensor.